MCP Connector for Advance Steel Documentation
Complete guide to installing, configuring, and using MCP Connector for Advance Steel - 236 tools by default, including the 43 free read-only tools, driven by Claude Desktop, ChatGPT Desktop, Cursor, or Claude Code.
Supported Advance Steel Versions
- Advance Steel 2022
- Advance Steel 2023
- Advance Steel 2024
- Advance Steel 2025
- Advance Steel 2026
- Advance Steel 2027
If you work in plain AutoCAD rather than Advance Steel, use MCP Connector for AutoCAD instead. That one covers AutoCAD 2022 to 2027. This connector already contains the AutoCAD drawing tools, so inside Advance Steel you do not need both. Each connector has its own licence.
AI Applications
- Claude Desktop
- ChatGPT Desktop
- Cursor
- Claude Code
- VS Code (GitHub Copilot agent mode)
- Visual Studio 2022 17.14+ / 2026 (GitHub Copilot)
- GitHub Copilot CLI
- Grok Build (xAI CLI)
Installation
Make sure all running instances of Autodesk Advance Steel are closed before starting the installation.
.exe file and follow the installation wizard, accepting the licence agreement and privacy policy.MCPCONNECTORADVS_STATUS at the command line confirms it is running, and MCPCONNECTORADVS_START starts it if it is not.
Silent Deployment
IT teams can install MCP Connector for Advance Steel without prompts using a software deployment tool or script.
The installer uses its own command-line switches. Installing silently requires both /S and /ACCEPTEULA.
Install
AUTOM8LABS_MCPConnectorAdvanceSteel_v<version>.exe /S /ACCEPTEULA /versions=2025,2026 /log=C:\Logs\MCPConnectorAdvanceSteel.log
Replace <version> with the installer version.
Uninstall
AUTOM8LABS_MCPConnectorAdvanceSteel_v<version>.exe /uninstall /S
Command-line switches
| Switch | Description |
|---|---|
/S | Runs Setup without a user interface. |
/ACCEPTEULA | Required for silent installation. Accepts the licence agreement and privacy policy, and records acceptance in the log. Without it, Setup installs nothing and returns exit code 2. |
/versions=2025,2026 | Optional. Installs for the specified Advance Steel versions. Omit this switch to install for every supported version. |
/log=C:\Logs\MCPConnectorAdvanceSteel.log | Sets the log file path. If omitted, the log is saved in the temporary folder of the account running Setup, normally C:\Windows\Temp for the SYSTEM account. |
/uninstall | Uninstalls the connector. Combine with /S to uninstall without a user interface. |
/? | Displays the available switches. |
Exit codes
| Code | Meaning |
|---|---|
0 | Finished successfully. |
1 | Unexpected error. Check the log. |
2 | /ACCEPTEULA was missing. Nothing was installed. |
3 | The installer could not read its product settings. Download the installer again. |
4 | Setup stopped or the installation failed. Check the log. |
5 | The /versions= value is not a valid list of years. |
Before you deploy
- Run Setup with administrator rights. Deployment tools can run it using the SYSTEM account.
- Close Advance Steel and any AI app using the connector. If either is open, Setup returns exit code
4before changing any files. You can run it again once the applications are closed.
After installation
Connect each user’s AI app. AI app connections are configured per user. After a silent installation, each user must connect their AI app using the MCP Connector button, as described in Enabling MCP.
Activate the licence. Silent installation does not activate a licence. Enter the licence key in the connector as usual.
Enabling MCP Connector for Advance Steel
After installation, click the MCP Connector button in the Plug-ins tab to open the connector dialog, then toggle Enable MCP to start the connection. No licence key is needed for the free tools - the key only unlocks the Pro set.
The dialog shows the status of detected AI applications:
- Ready (Running) - The AI application is configured to reach Advance Steel and is currently open
- Ready - Configured, but the application is not running right now
- Detected - The application is installed but not yet configured; toggle Enable MCP to configure it
- Not Detected - The AI application is not installed on this machine
The indicator at the top of the dialog reads Disabled, Waiting, or Active. Toggling Enable MCP off again removes the connector from every detected client's configuration.
Configuration
MCP Connector for Advance Steel includes one-click auto-configuration for supported AI applications. Toggling Enable MCP in the connector dialog writes the configuration for every detected application at once. The installer also registers the server on install, so in most cases there is nothing to do by hand.
Claude Desktop
The config file is located at:
%APPDATA%\Claude\claude_desktop_config.json
The Microsoft Store build never reads %APPDATA%\Claude - Windows redirects that folder into a sandboxed package location. MCP Connector for Advance Steel detects the Store package and writes to both paths, so the Store build is configured automatically. The redirected file lives here:
%LOCALAPPDATA%\Packages\Claude_<hash>\LocalCache\Roaming\Claude\claude_desktop_config.json
If tools still do not appear, fully quit Claude from the system tray (closing the window is not enough) and reopen it.
ChatGPT Desktop
ChatGPT appears in the dialog when it is installed on your machine. The config file is located at:
%USERPROFILE%\.codex\config.toml
This file is shared with the Codex CLI, so configuring ChatGPT Desktop makes the Advance Steel tools available in Codex CLI as well. After configuring, fully quit ChatGPT and reopen it. With Advance Steel open and a drawing loaded, a quick test is to ask ChatGPT to "Check the connection to Advance Steel".
Use a local Work conversation on the computer running Advance Steel. In ChatGPT Desktop, open Settings > MCP servers and check that AUTOM8LABS_AdvanceSteel is enabled, then select Restart. Type /mcp in the conversation to check the connection. ChatGPT in a web browser does not read this local configuration. See the official MCP setup guide.
Cursor
The config file is located at:
%USERPROFILE%\.cursor\mcp.json
GitHub Copilot
GitHub Copilot appears in the dialog when VS Code, Visual Studio, or the Copilot CLI is installed on your machine. The config files are located at:
%APPDATA%\Code\User\mcp.json
%USERPROFILE%\.mcp.json
%USERPROFILE%\.copilot\mcp-config.json
Grok Build
Toggle Enable MCP and the connector writes its entry into xAI's Grok Build CLI configuration automatically. The config file is located at:
%USERPROFILE%\.grok\config.toml
Grok Build also reads Claude Code's and Cursor's MCP config, so if you have already configured either of those the connector shows up in Grok Build with no extra step.
Claude Code & other MCP clients
MCP Connector for Advance Steel exposes a standard MCP stdio server, so it also works with Claude Code, VS Code, and any other MCP-compatible client. The server is a single executable installed with the plug-in bundle:
C:\Program Files\Autodesk\ApplicationPlugins\AUTOM8LABS.MCPConnectorAdvanceSteel.bundle\Contents\Bridge\MCPConnectorAdvanceSteel.Bridge.exe
Register it in Claude Code from a terminal:
claude mcp add AUTOM8LABS_AdvanceSteel -- "C:\Program Files\Autodesk\ApplicationPlugins\AUTOM8LABS.MCPConnectorAdvanceSteel.bundle\Contents\Bridge\MCPConnectorAdvanceSteel.Bridge.exe"
Manual configuration (any MCP client)
Add this to your client's MCP server configuration:
{
"mcpServers": {
"AUTOM8LABS_AdvanceSteel": {
"command": "C:\\Program Files\\Autodesk\\ApplicationPlugins\\AUTOM8LABS.MCPConnectorAdvanceSteel.bundle\\Contents\\Bridge\\MCPConnectorAdvanceSteel.Bridge.exe"
}
}
}
VS Code
VS Code uses a slightly different shape. Add the server to your MCP configuration (for example .vscode/mcp.json in a workspace):
{
"servers": {
"AUTOM8LABS_AdvanceSteel": {
"type": "stdio",
"command": "C:\\Program Files\\Autodesk\\ApplicationPlugins\\AUTOM8LABS.MCPConnectorAdvanceSteel.bundle\\Contents\\Bridge\\MCPConnectorAdvanceSteel.Bridge.exe"
}
}
}
After changing MCP configuration, restart the AI client completely for the changes to take effect.
Optional: raw command execution
Two tools can drive the host directly: execute_command runs a raw command string as if
typed at the command line, and execute_lisp evaluates an AutoLISP expression. Because they
can drive anything, both are disabled by
default: they are neither listed nor callable until you opt in on that machine by
setting MCP_CONNECTOR_ENABLE_COMMAND_EXEC=1 in the MCP client configuration.
Even when enabled, code-loading and shell verbs (NETLOAD, APPLOAD, SCRIPT, SHELL, AutoLISP
load) are blocked. Both tools are Pro, so a licence is needed as well as the opt-in.
After saving the configuration, fully quit and reopen your AI client - quit it from the system tray rather than just closing the window, or it keeps the old environment and the two tools still will not appear. To turn them off again, remove the setting and restart the client the same way.
{
"mcpServers": {
"AUTOM8LABS_AdvanceSteel": {
"command": "C:\\Program Files\\Autodesk\\ApplicationPlugins\\AUTOM8LABS.MCPConnectorAdvanceSteel.bundle\\Contents\\Bridge\\MCPConnectorAdvanceSteel.Bridge.exe",
"env": {
"MCP_CONNECTOR_ENABLE_COMMAND_EXEC": "1"
}
}
}
}
Optional: read-only session
A read-only session withholds every tool that can change a drawing or the steel model. With a Pro licence that leaves 67 tools: the 43 free tools plus the steel queries and exports (objects, assemblies, numbering status, the catalogue, the drawing register, the dimensions and labels on a detail drawing and the material list). A withheld tool is not listed to the AI client at all, and is refused by name if it is called anyway, so the AI cannot reach a write.
It is worth using whenever the drawings belong to a client rather than to you. DWG is usually the format that arrives from someone else. An in-session change can still be undone in Advance Steel, but the folder tools save each drawing as they go, so those edits are on disk already - and an unwanted change does not always announce itself on screen.
Turn it on with the Read-Only Session checkbox in the connection
dialog, or by running MCPCONNECTORADVS_READONLY at the Advance Steel command line.
Either way, reconnect your AI client afterwards so it refreshes its
tool list.
Locking it on for a team. An administrator can enforce read-only across a computer using ForceReadOnly. See Admin Permissions below.
Claude Desktop Settings
MCP Connector for Advance Steel exposes 236 tools, plus two optional command-execution tools that stay disabled until you opt in. In Claude Desktop, enable Load tools when needed so tools are loaded on demand rather than all at once.
Use Chat, not Cowork
Claude Desktop has a mode selector at the bottom of the message box: Chat and Cowork. MCP connectors run in Chat conversations. In Cowork, your Advance Steel requests will not reach the connector and Claude behaves as if Advance Steel is not connected - even though the connector is configured correctly. Before you start, check the selector is set to Chat.
Note this is the opposite way round to ChatGPT Desktop, where the Advance Steel tools are available in Work rather than regular Chat.
Local AI Setup
Connect a local AI model to Advance Steel through an MCP-compatible app. These steps are for Windows, on the same computer as Advance Steel.
1. Prepare Advance Steel
- Install MCP Connector for Advance Steel and open a sample drawing.
- On the Plug-ins tab, click MCP Connector and turn on Enable MCP. Keep Advance Steel open.
- In your AI app, download or select a local model that supports tool calling.
2. Configure your app
Use this entry for Advance Steel 2022 to 2027.
{
"mcpServers": {
"AUTOM8LABS_AdvanceSteel": {
"command": "C:\\Program Files\\Autodesk\\ApplicationPlugins\\AUTOM8LABS.MCPConnectorAdvanceSteel.bundle\\Contents\\Bridge\\MCPConnectorAdvanceSteel.Bridge.exe"
}
}
}
For separate fields, use AUTOM8LABS_AdvanceSteel as the name, stdio as the transport, and the command path with single backslashes and no quotes. Leave Arguments blank for this example.
Edit an existing connector entry rather than adding a duplicate. Keep its arguments, environment and tool settings. In an existing JSON file, add only AUTOM8LABS_AdvanceSteel inside mcpServers, preserving other entries.
Choose your app below. Connection tested means registration, tool discovery and reconnection were checked using the Revit connector. These Advance Steel steps use the same app settings; they have not been tested end to end with every app and model.
- Open Settings > Agent Skills once to create the configuration file.
- Click the app version number > Open storage. Open
plugins/anythingllm_mcp_servers.jsonand add the entry. - Return to Agent Skills and click Refresh. Check the connector is running.
- Start your test prompt with
@agent.
- Open MCP connections and look for
AUTOM8LABS_AdvanceSteel, including paused entries. - Use that connection if present. Otherwise, add one using the name and command above.
- Enable the connection and choose your local model.
- Open Settings > MCP > MCP Servers > Add > Import from JSON.
- Paste the JSON, enable the server and check its tools appear.
- Open Work > your Agent's menu > Edit > MCP and enable the connector for that Agent.
- Select your local model and start a conversation with that Agent.
- Open Settings > MCP Servers > Add MCP Server.
- Select STDIO and enter the name and command above.
- Save, then enable the server. A green indicator confirms it is active.
- In the right sidebar, open Program > Install > Edit mcp.json.
- Add the connector inside
mcpServersand save. - Check the connector is available and enabled for your chat.
- Sign in to your local installation. Open MCP settings > Import JSON.
- Paste the JSON. The import applies immediately.
- Enable the connector and MCP tool use for your chat.
These steps apply to 2026.9.11. Other versions may differ. See Unsloth's current guide.
3. Test the connection
With your sample drawing open, ask:
Use the Advance Steel connector to tell me the active drawing name and Advance Steel version. Do not change anything.
In AnythingLLM, prefix this with @agent. Confirm a connector tool runs and the answer matches your open drawing.
Tool loading and model limits
If available, enable tool selection or on-demand loading and start with a few read-only tools. Large tool lists can exceed a local model's context. A larger context setting alone does not guarantee reliable tool use.
Operator Skill
An operator skill is a plain text playbook Claude reads before touching your drawing. It teaches Claude to use the connector efficiently: read in bulk instead of one entity at a time, verify answers with counts, batch edits in one call, and say so instead of guessing when something cannot be done. The result is fewer calls, fewer dead chats, and far less of your usage allowance burned on a single question.
The free Advance Steel operator skill covers the drawing tools and the steel tools.
Install in Claude Desktop:
- Download the skill: Advance Steel Connector Skill
- In Claude Desktop, go to Settings > Skills > Add > Upload a skill and select the zip.
- That is it - Claude picks the skill up automatically in new chats. If you ever find it has not, mention it in your prompt, for example "Follow the advance-steel-connector skill".
Using another AI client? Extract the ZIP and add the skill folder to your AI client. Browse all MCP Skills.
Quickstart
MCPCONNECTORADVS_STATUS confirms it is running.ping tool. You should get back a confirmation that it is connected.Power BI Dashboard
A free browser dashboard and Power BI report for tool-use records. MCP Connector Pro is required to record audit logs.
Tool Use Audit dashboard
Review AI-assisted work in Advance Steel using a browser dashboard or Power BI.
Requires: MCP Connector for Advance Steel Pro 1.0.0+ and administrator rights to enable logging.
Download: Tool Use Audit v1.0.0 (.zip)
1. Enable logging
Logging is off by default. On each computer, open Registry Editor as administrator. Create this key if needed, then set its values:
HKEY_LOCAL_MACHINE\SOFTWARE\AUTOM8LABS\MCPConnectorAdvanceSteel
| Value name | Type and setting |
|---|---|
AuditLog | DWORD (32-bit): 1 |
AuditLogFolder | String (REG_SZ): your log folder, e.g. C:\AuditLogs |
Create the log folder and give Advance Steel users write access. For multiple computers, use a network share. Restart Advance Steel.
2. Open a dashboard
Extract the ZIP to C:\AuditDashboard or another short path. Keep its files and folders together.
- Open
audit-dashboard.htmlin Chrome or Edge. - Select Open audit folder, choose your
AuditLogFolderand allow read access.
The dashboard reads files locally and refreshes automatically.
- Open
AUTOM8LABS Connector Audit.pbipin Power BI Desktop for Windows (September 2026 or later). - Under Transform data > Edit parameters, set AuditLogFolder to your log folder.
- Select OK > Apply changes > Refresh.
Select Refresh whenever you want the latest records.
3. Check logging works
Ask your AI assistant to run get_drawing_info in your open Advance Steel drawing. Wait around 30 seconds, then check for the call. Select Refresh in Power BI.
Time, user, computer, host and release, drawing, AI app, tool, read/write type and outcome, plus the first 300 characters of its arguments. Chat messages, full tool results and bridge-only connection calls are excluded.
Write means the tool can change a drawing; it does not prove a change occurred. Optional: set AuditReason (DWORD) to 1 in the same registry key, then restart Advance Steel, to request a short explanation from the AI.
CSV files are saved under %LOCALAPPDATA%\AUTOM8LABS\MCPConnectorAdvanceSteel\Audit, then copied into month folders under AuditLogFolder every 30 seconds and when Advance Steel closes. Failed copies retry automatically for files updated within the last seven days.
Local copies are kept for 90 days. Files in your chosen folder are not automatically deleted. See the included README for more detail.
Want your company branding? Contact us.
Tool Reference
MCP Connector for Advance Steel includes the tool set of MCP Connector for AutoCAD: drawings, layers, blocks, annotation, layouts and plotting, external references and the Management Pack, with a read-only free tier that works without a licence. Those tools work the same way in Advance Steel and are not repeated here. One difference: redo is not available in Advance Steel, so save a separate copy before an undo or a rollback if you may need the current state again. See the AutoCAD Tool Reference for the list.
The tools below are the steel tools, grouped by category. Every tool name shown is the exact identifier exposed to your AI client. The Edition column shows whether a tool is available in the free edition or needs a Pro licence. Under each description is an example prompt showing how to ask for it in natural language - click any prompt to copy it, paste it into your AI client, and adjust the names and numbers to suit your drawing.
Steel model and drawings
These tools exist only because the host is Advance Steel. Every one of them needs a Pro
licence. Property changes, section changes, applying an annotation template and deleting
dimensions and labels default to a preview (dry_run: true). Review the proposed
changes before asking the AI to apply them. Numbering, creating drawings, creating beams and
plates, and adding a single dimension or label take effect immediately.
Steel: Annotation templates
A template holds the dimensions and labels of one finished drawing, each stored relative to its view. Applying it to the drawing of a similar assembly moves each point onto the nearest real point of the same sort and reports anything that has no match. It is a matching rule for similar assemblies, not a guarantee: check the result. Applying a template again adds only what is missing.
| Tool | Example prompt | Edition |
|---|---|---|
| Put the dimensions and labels of a saved annotation template onto the open Advance Steel detail drawing, re-creating each with Advance Steel's own dimension and label commands at the matching place in this drawing's views | ||
apply_annotation_template | Preview the column-base template on this drawing and tell me what has no match | Pro |
| List the annotation templates saved on this machine with save_annotation_template: name, the drawing each was saved from, when, and how many views, dimensions and labels it holds | ||
list_annotation_templates | Which annotation templates are saved on this machine? | Pro |
| Save the dimensions and labels of the open Advance Steel detail drawing as a named annotation template, so the same dimensioning and labelling can be applied to drawings of similar assemblies with apply_annotation_template | ||
save_annotation_template | Save the dimensions and labels of this drawing as a template called column-base | Pro |
Steel: Assemblies and numbering
| Tool | Example prompt | Edition |
|---|---|---|
| Read one Advance Steel assembly in full, by its assembly mark or by the handle of any of its parts: the main part, every part attached to it in the shop with its part mark, section or thickness, length, material and weight, the shop bolts and welds that hold it together, the total weight, how many identical assemblies are in the model with the handles of their main parts, and the drawings that detail it | ||
get_assembly | Show me assembly C11 in full: every part, bolt and weld, and the drawings that detail it | Pro |
| Report the numbering state of the Advance Steel model: whether numbering is up to date, how many parts have a part mark and an assembly mark and how many do not, how many distinct part marks and assembly marks exist, the current numbering settings (start numbers, increments and whether single parts and assemblies are numbered), and a sample of the unnumbered parts | ||
get_numbering_status | Is numbering up to date? How many parts have no mark? | Pro |
| List the assemblies in the Advance Steel model, one row per assembly mark: the mark, how many identical assemblies carry it, what the main part is (kind, role, section or thickness, length), how many parts are attached to it in the shop, the total weight of one assembly, and the drawings that already detail it | ||
list_assemblies | List the assemblies whose mark starts with C, with their main part and weight | Pro |
| Run Advance Steel numbering on the model: identical parts get the same part mark and identical assemblies the same assembly mark, using the prefixes and method configured in Advance Steel. In Advance Steel 2022, run Numbering in Advance Steel itself: the connector reads the marks but cannot start numbering in that release | ||
run_steel_numbering | Run numbering for single parts and assemblies, then tell me how many parts carried marks before and after | Pro |
Steel: Catalogue
| Tool | Example prompt | Edition |
|---|---|---|
| List the section classes in the Advance Steel catalogue installed on this machine (for example UK universal beams, European HEA, square hollow sections), with the shape family of each | ||
list_section_classes | Which section classes are in the catalogue on this machine? | Pro |
| List the section sizes in one Advance Steel section class, with depth, width and weight per metre where the catalogue carries them | ||
list_sections | List the sizes in the universal beams class that start with UB406 | Pro |
| List the materials defined in the Advance Steel catalogue (steel grades and the rest) by the name set_steel_object_properties and the create tools take | ||
list_steel_materials | List the materials that start with S355 | Pro |
| List the model roles defined in the Advance Steel catalogue (Column, Rafter, Purlin, Base plate and so on) by the key set_steel_object_properties and the create tools take, with the description of each | ||
list_steel_roles | Which model roles can I assign? List them with their descriptions | Pro |
Steel: Dimensions and labels
These tools work on the detail drawing that is open in Advance Steel. Dimensions and labels are created by Advance Steel's own commands, so they are real Advance Steel objects that belong to their view. Linear dimensions and leader labels are read and created. Angular and arc dimensions, level marks, weld symbols and section marks are not. The wording of a new label comes from Advance Steel's label definition for the object it lands on. When a drawing is updated, Advance Steel re-checks manually added dimensions and, with its default settings, can remove them or drop points from them, so add dimensions after the last update or keep them in an annotation template and apply it again afterwards. Labels are not affected.
| Tool | Example prompt | Edition |
|---|---|---|
| Add an Advance Steel dimension to a view on the open detail drawing, the same object the Labels & Dimensions commands create, so it belongs to the view | ||
add_detail_dimension | Add a chain dimension along the bottom of view 1 through every hole centre | Pro |
| Add an Advance Steel label to an object in a view on the open detail drawing, the same object the Insert Label command creates | ||
add_detail_label | Label the end plate in view 3 and put the text to the right of it | Pro |
| Delete Advance Steel dimensions and labels from the open detail drawing by handle (from list_detail_dimensions and list_detail_labels) | ||
delete_detail_annotations | Delete the two vertical dimensions on view 1, and show me what would go first | Pro |
| The outcome of the most recent add_detail_dimension, add_detail_label or apply_annotation_template in this Advance Steel session | ||
get_detail_annotation_report | Did those dimensions and labels get created? Show me the outcome of each one | Pro |
| Read the drawn outline of one view on the open detail drawing as the points a dimension or label can attach to: the end points of its lines (points) and the centres of its holes (holes), in sheet millimetres | ||
get_detail_view_geometry | Give me the points and hole centres of view 2 so we can dimension it | Pro |
| List the Advance Steel dimensions on the open detail drawing | ||
list_detail_dimensions | List the dimensions on this drawing, view by view, with the values they show | Pro |
| List the Advance Steel labels on the open detail drawing | ||
list_detail_labels | List the labels on this drawing and what each one says | Pro |
Steel: Drawings
| Tool | Example prompt | Edition |
|---|---|---|
| Create Advance Steel detail drawings by running a drawing process, the same as choosing it from the Drawing Processes palette | ||
create_steel_drawings | Create detail drawings for assemblies C10 and C11 using the process I picked | Pro |
| Describe the Advance Steel detail drawing that is open: the model it was generated from, the paper size, each view on the sheet with its position, size and scale and whether it lies on the paper, how many dimensions and labels each view carries, the title texts, and a count of every other Advance Steel detailing object (weld symbols, level symbols, lists, revision table) | ||
get_detail_drawing_info | Describe the detail drawing I have open: sheet size, views and whether any view is off the paper | Pro |
| List the Advance Steel drawing processes installed on this machine | ||
list_drawing_processes | List the drawing processes for selected assemblies and tell me which ones choose their own sheet size | Pro |
| List the Advance Steel drawing styles installed on this machine: the rule sets that decide which views a detail gets and how it is dimensioned and labelled automatically | ||
list_drawing_styles | Which drawing styles are installed for assemblies? | Pro |
| List the documents Advance Steel has generated from this model and registered to it, the contents of the Document Manager: detail drawings, lists and NC files | ||
list_steel_documents | List the detail drawings registered to this model and which assembly each one shows | Pro |
Steel: Export
| Tool | Example prompt | Edition |
|---|---|---|
| Build a material list of the Advance Steel model grouped by part mark: mark, quantity, kind, section or plate thickness, length, width, material, coating, weight each and total weight, and the assembly marks the part appears in | ||
export_steel_material_list | Build a material list grouped by part mark and save it as a spreadsheet in the job folder | Pro |
Steel: Model and objects
| Tool | Example prompt | Edition |
|---|---|---|
| Change the section of one or more existing Advance Steel beams to another size, keeping their position, cuts and connections | ||
change_beam_section | Change the selected rafters to UB457x191x67 and show me the before and after first | Pro |
| Create an Advance Steel straight beam (a beam, column, brace or any straight member) between two points in the model, in millimetres and world coordinates | ||
create_steel_beam | Create a UB254x146x31 beam from 0,0,3000 to 6000,0,3000 with the role Beam | Pro |
| Create an Advance Steel plate in the model, in millimetres and world coordinates | ||
create_steel_plate | Create a 300 by 200 plate, 15 thick, centred at 0,0,0 in S355JR | Pro |
| Describe the objects the user has selected in Advance Steel as steel objects: kind, role, section or thickness, material, part mark and assembly mark for each | ||
get_selected_steel_objects | What have I got selected? List each object with its section and marks | Pro |
| Summarise the Advance Steel content of the active drawing | ||
get_steel_document_info | What is in this Advance Steel model? Give me the counts before we start | Pro |
| Read one Advance Steel object in full by its handle (the steel object's handle or the handle of the entity that draws it): identity, role, material, coating, part mark and assembly mark with their prefixes, quantity in the model, weight, and the geometry that defines it | ||
get_steel_object | Read the full properties of beam 2F3A: section, material, marks and weight | Pro |
| Read the Advance Steel project data of the model: project name and number, client, building and its location, contractor, order and construction dates, designer, drawn by and the five project user attributes | ||
get_steel_project_data | What project data is set on this model? | Pro |
| List the Advance Steel objects in the model as steel objects, not generic entities: beams with section, length and weight; plates with thickness and size; bolt patterns with standard, grade, diameter and count; anchors, welds, shear studs, special parts, grids and connections | ||
list_steel_objects | List every beam with the role Column, with its section, length and assembly mark | Pro |
| Select Advance Steel objects in the drawing by handle so the user can see which ones were meant, replacing the current selection | ||
select_steel_objects | Select the plates you just listed so I can see them in the model | Pro |
| Set properties on one or more Advance Steel objects: material, coating, model role, note, name (denotation), item number, lot or phase, the part mark prefix and assembly mark prefix, layer, and the ten user attributes | ||
set_steel_object_properties | Set the material of every beam with the role Purlin to S355JR, and show me the changes before you apply them | Pro |
| Set Advance Steel project data fields on the model | ||
set_steel_project_data | Set the project number to 2417 and the drawn by field to JG | Pro |
FAQ
MCPCONNECTORADVS_LICENCE command, then restart your AI client.
Changelog
The drawing tools of MCP Connector for AutoCAD 2.2.2, and Group Policy for administrators (236 tools)
- The AutoCAD drawing tools match MCP Connector for AutoCAD 2.2.2. Every drawing tool in that release is included and works the same way in Advance Steel. See the AutoCAD Tool Reference
- New: work across open drawings.
list_open_drawings,activate_drawingandclose_drawing - New:
write_block,import_layoutandimport_pdf. Write a selection to a new DWG keeping its coordinates. Bring a layout with its page setup from a DWT or a DWG. Import a PDF page as geometry, with a crop window and a minimum text size - Blocks. New
get_block_definitionreads what is inside a definition and where it is used, anddelete_block_definitionremoves one that nothing uses - Text and layouts. New
measure_textgives the size text takes up in its style,set_text_justificationchanges what text is justified about and leaves it where it is, andreorder_layoutssets the tab order - New:
get_session_info. Reports the connector version and edition, the active drawing, whether the session is read-only and the administrator policy in force - New: Group Policy. The installer provides a Group Policy template, so tool permissions can be set for computers or for chosen users through Group Policy or Intune. A user policy can only tighten what the computer allows. See Administrator Tool Permissions
- Advance Steel 2022 to 2027
First public release
- New drawings. Drawing-register queries handle native initialisation without saving changes or clearing existing edits
- Safer updates. Silent setup checks for a running CAD host or locked bridge before removing installed files
- Administration. Pro audit logging, HTML and Power BI reports, registry allow/block lists and enforced read-only sessions
- Steel model. Read beams, plates, bolts, anchors and welds as steel objects with their sections, materials, roles, marks and weights, and read an assembly with every part attached to it in the shop
- Numbering and drawings. Report the numbering state, run numbering, create detail drawings with a drawing process and list the documents registered to the model
- Dimensions and labels. Read the dimensions and labels on a detail drawing and add real Advance Steel dimensions and labels to its views
- Annotation templates. Save the dimensions and labels of a finished drawing and apply them to the drawings of similar assemblies
- Editing. Set material, coating, role and other properties, change beam sections, and create beams and plates
- Material list grouped by part mark, with the bolts on a second sheet, exported to a spreadsheet
- The AutoCAD drawing tools are included, so inside Advance Steel this is the only connector you need
- Bulk edits preview before they write and report what they would change
- Advance Steel 2022 to 2027